Tandberg Data DPS Expansion Module Disk Pack Spezifikationen Seite 61

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 60
| 55
To perform an LED self test
Press the Alarm Reset button when no error conditions are occurring.
The test will terminate if you press the button again or if an error condition occurs while the
self test is running.
During the self test, you will hear two beeps followed by the illumination of the System Fault,
Logical Fault, and Box Identify LEDs. The Drive Carrier lower Fault LEDs (amber) will flash
continuously during the test.
RAID controller module LEDs
The following table lists the RAID Controller Module LED icons and status indicators:
ON - ON - Drive Fault LED. Drive failure has
occurred causing
loss of availability or
redundancy.
ON - ON - Array is performing
background function
such as a parity
check, initialization,
or expansion.
- - - Blinking Enclosure
identification mode.
When illuminated it
identifies the
specific enclosure.
LED/Icon Description
Battery Fault This LED appears between the controller’s
Ethernet and RS232 ports.
Illuminated - Backup battery has low voltage, has
experienced a timeout on charge indicating a faulty
battery, or has experienced a fault in the charging
circuitry.
Cache Active This LED appears between the controller’s
Ethernet and RS232 ports.
Illuminated - RAID controller cache has data saved
in memory but not written to the array.
OPS Panel LEDs
Other Associated
LEDs or Alarms
State Description
Power
On
(Green)
System
Fault
(Amber)
Logical
Fault
(Amber)
Box
Identify
(Blue)